{"id":5429,"date":"2026-08-15T08:00:00","date_gmt":"2026-08-15T00:00:00","guid":{"rendered":"https:\/\/www.aox-actuator.com\/?p=5429"},"modified":"2026-08-31T17:33:15","modified_gmt":"2026-08-31T09:33:15","slug":"wire-electric-actuator-4-20ma-signal-control","status":"publish","type":"post","link":"https:\/\/www.aox-actuator.com\/tr\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/","title":{"rendered":"4-20mA Sinyal Kontrol\u00fc \u0130\u00e7in Elektrikli Akt\u00fcat\u00f6r Nas\u0131l Kablolan\u0131r?"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>H\u0131zl\u0131 Cevap<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir elektrikli akt\u00fcat\u00f6r 4-20mA sinyalini kablolamak i\u00e7in, \u00fcreticinin kablolama \u015femas\u0131na g\u00f6re kontrol cihaz\u0131n\u0131n pozitif terminalini akt\u00fcat\u00f6r\u00fcn pozitif analog giri\u015fine ba\u011flay\u0131n. D\u00f6n\u00fc\u015f kablosunu kontrol cihaz\u0131n\u0131n negatif terminaline y\u00f6nlendirerek analog d\u00f6ng\u00fcy\u00fc tamamlay\u0131n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Islak bir proses tesisindeki kontrol d\u00f6ng\u00fcs\u00fcn\u00fcn k\u00f6t\u00fc d\u00fczenlenmesi, sinyal sapmas\u0131na neden olarak erken valf a\u015f\u0131nmas\u0131na yol a\u00e7acakt\u0131r. Kurulum, akt\u00fcat\u00f6r\u00fcn \u00e7al\u0131\u015fmas\u0131ndaki elektromanyetik giri\u015fimin neden oldu\u011fu herhangi bir rahats\u0131zl\u0131\u011f\u0131 \u00f6nlemek i\u00e7in blendajl\u0131 b\u00fck\u00fcml\u00fc \u00e7ift kablolama kullanmal\u0131d\u0131r.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"680\" src=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-1200x680.webp\" alt=\"Hassas 4-20mA sinyal kontrol\u00fc i\u00e7in AOX elektrikli valf akt\u00fcat\u00f6r\u00fc\" class=\"wp-image-5430\" srcset=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-1200x680.webp 1200w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-500x283.webp 500w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-300x170.webp 300w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-768x435.webp 768w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-1536x870.webp 1536w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-18x10.webp 18w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-132x75.webp 132w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-480x272.webp 480w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1-800x453.webp 800w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp 1667w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Elektrikli Akt\u00fcat\u00f6rler \u0130\u00e7in 4-20mA Kontrol Nedir?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir <a href=\"https:\/\/www.aox-actuator.com\/tr\/product\/aox-vr-series-electric-actuator\/\" target=\"_blank\" rel=\"noreferrer noopener\">elektrikli akt\u00fcat\u00f6r 4-20mA kontrol sistemi<\/a> uzun kablolar \u00fczerindeki voltaj d\u00fc\u015f\u00fc\u015flerine kar\u015f\u0131 ak\u0131m sinyalinin ba\u011f\u0131\u015f\u0131kl\u0131\u011f\u0131 nedeniyle proses otomasyonunda yayg\u0131n olarak uygulan\u0131r. Do\u011fru 4-20mA elektrikli akt\u00fcat\u00f6r kablolamas\u0131, kontrol cihaz\u0131 kart\u0131n\u0131n do\u011fru bir konum komutu almas\u0131n\u0131 garanti eder.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Terminal kart\u0131 sonland\u0131rmas\u0131 i\u00e7in \u00f6nceden yal\u0131t\u0131lm\u0131\u015f y\u00fcks\u00fcklerin kullan\u0131lmas\u0131, kart\u0131 y\u0131pranm\u0131\u015f kablolardan korumaya yard\u0131mc\u0131 olacakt\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>4-20mA Mod\u00fcle Kontrol Nas\u0131l \u00c7al\u0131\u015f\u0131r?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mod\u00fcle elektrikli akt\u00fcat\u00f6r sinyali, valf konumunu 16mA'l\u0131k bir aral\u0131k boyunca do\u011frusal olarak e\u015fler. Standart yap\u0131land\u0131rmalarda, 4mA tam kapal\u0131 bir valfi (0% seyahat) temsil ederken, 20mA tam a\u00e7\u0131k bir valfe (100% seyahat) kar\u015f\u0131l\u0131k gelir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12mA gibi orta menzilli sinyaller, do\u011frusal bir yap\u0131land\u0131rmada tipik olarak seyahate kar\u015f\u0131l\u0131k gelir, ancak ters \u00e7al\u0131\u015fan kurulumlar yan\u0131t\u0131 tersine \u00e7evirebilir. Akt\u00fcat\u00f6r\u00fcn dahili mikroi\u015flemcisi bu ak\u0131m\u0131 izler ve <a href=\"https:\/\/www.aox-actuator.com\/tr\/blog\/how-gearbox-reducer-work\/\" target=\"_blank\" rel=\"noreferrer noopener\">di\u015fli motor <\/a>bu analog de\u011feri tam olarak e\u015fle\u015ftirmek i\u00e7in. End\u00fcstriyel proses \u00f6l\u00e7\u00fcm ve kontrol\u00fcnde standartla\u015ft\u0131r\u0131lm\u0131\u015f analog ak\u0131m sinyallerinin kullan\u0131m\u0131 IEC 60381-1 taraf\u0131ndan kapsanmaktad\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Kablolama \u015eemas\u0131: 4-20mA'y\u0131 Elektrikli Akt\u00fcat\u00f6re Ba\u011flama<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Muhafaza i\u00e7inde, terminal bloklar\u0131 entegre 4-20mA valf konumland\u0131r\u0131c\u0131 karta do\u011frudan ba\u011flan\u0131r. Ham iletkenleri a\u00e7\u0131\u011fa \u00e7\u0131karmadan yeterli kablo esnekli\u011fi sa\u011flamak i\u00e7in d\u0131\u015f ceketi \u00fcreticinin belirtti\u011fi uzunlu\u011fa kadar soyun.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"626\" src=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-1200x626.webp\" alt=\"4-20mA elektrikli valf akt\u00fcat\u00f6r\u00fc ad\u0131m ad\u0131m kablolama \u015femas\u0131\" class=\"wp-image-5431\" srcset=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-1200x626.webp 1200w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-500x261.webp 500w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-300x156.webp 300w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-768x401.webp 768w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-1536x801.webp 1536w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-18x9.webp 18w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-144x75.webp 144w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-480x250.webp 480w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1-800x417.webp 800w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image1.webp 1737w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Genellikle, toprak d\u00f6ng\u00fcs\u00fc giri\u015fimi riskini azaltmak i\u00e7in b\u00fck\u00fcml\u00fc \u00e7ift blendaj\u0131n\u0131 PLC ucunda topraklay\u0131n. Nemin girmesini \u00f6nlemek i\u00e7in her zaman muhafaza contas\u0131n\u0131 inceleyin ve s\u0131zd\u0131rmazl\u0131k y\u00fczeylerini temizleyin.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>4-20mA vs 0-10V vs Modbus: Sinyal Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hat d\u00fc\u015f\u00fc\u015f\u00fcnden etkilenen voltaj sinyallerinin aksine, ak\u0131m d\u00f6ng\u00fcleri geni\u015f tesislerde g\u00fcvenilirdir. Modbus gibi dijital protokoller daha zengin te\u015fhisler sunar ancak karma\u015f\u0131k adresleme gerektirir, bu da analog d\u00f6ng\u00fcleri daha basit hale getirir.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Sinyal Tipi<\/strong><\/td><td><strong>G\u00fcr\u00fclt\u00fc Ba\u011f\u0131\u015f\u0131kl\u0131\u011f\u0131<\/strong><\/td><td><strong>Mesafe S\u0131n\u0131r\u0131<\/strong><\/td><td><strong>Donan\u0131m Karma\u015f\u0131kl\u0131\u011f\u0131<\/strong><\/td><td><strong>En \u0130yi Kullan\u0131m<\/strong><\/td><\/tr><tr><td><strong>4-20mA Ak\u0131m<\/strong><\/td><td>Harika<\/td><td>Y\u00fcksek (Diren\u00e7le s\u0131n\u0131rl\u0131)<\/td><td>D\u00fc\u015f\u00fck (Basit 2 telli)<\/td><td>A\u011f\u0131r kimyasal i\u015flem<\/td><\/tr><tr><td><strong>0-10V Voltaj<\/strong><\/td><td>Fakir<\/td><td>\u00c7ok K\u0131sa (Voltaj d\u00fc\u015f\u00fc\u015f\u00fcne duyarl\u0131)<\/td><td>D\u00fc\u015f\u00fck (Ortak toprak gerektirir)<\/td><td>HVAC ve temiz odalar<\/td><\/tr><tr><td><strong>Modbus RTU<\/strong><\/td><td>Harika<\/td><td>Uzun (RS-485 al\u0131c\u0131-vericiye ba\u011fl\u0131)<\/td><td>Orta (Kontrol cihaz\u0131 yap\u0131land\u0131rmas\u0131 gerektirir)<\/td><td>\u00c7oklu cihaz a\u011flar\u0131<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bu tablo, proses d\u00f6ng\u00fcn\u00fcz i\u00e7in en etkili kontrol y\u00f6ntemini se\u00e7menize yard\u0131mc\u0131 olmak i\u00e7in temel parametreleri kar\u015f\u0131la\u015ft\u0131r\u0131r. Proses tesisleri, uzun mesafe hatlar\u0131nda g\u00fcvenilir, parazitsiz ileti\u015fim sa\u011flamak i\u00e7in ak\u0131m sinyallemesini \u00f6nceliklendirir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Yayg\u0131n Kablolama Sorunlar\u0131 ve Sorun Giderme<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"626\" src=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-1200x626.webp\" alt=\"4-20mA sinyal sorun giderme tablosu elektrikli valf akt\u00fcat\u00f6rleri i\u00e7in\" class=\"wp-image-5432\" srcset=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-1200x626.webp 1200w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-500x261.webp 500w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-300x157.webp 300w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-768x401.webp 768w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-1536x802.webp 1536w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-18x9.webp 18w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-144x75.webp 144w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-480x251.webp 480w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1-800x418.webp 800w, https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image2-1.webp 1736w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Saha devreye alma genellikle tesis ba\u015flatma programlar\u0131n\u0131 geciktiren kablolama hatalar\u0131n\u0131 ortaya \u00e7\u0131kar\u0131r. 0mA d\u00f6ng\u00fc ak\u0131m\u0131, devrede fiziksel bir kopukluk oldu\u011funu g\u00f6sterirken, d\u00fc\u015f\u00fck ak\u0131m y\u00fcksek diren\u00e7li ba\u011flant\u0131lar\u0131 veya zay\u0131f sonland\u0131rmalar\u0131 d\u00fc\u015f\u00fcnd\u00fcr\u00fcr.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sinyal mevcut ancak valf davran\u0131\u015f\u0131 karars\u0131z ise, blendaj topraklama d\u00f6ng\u00fclerini veya biti\u015fik AC g\u00fc\u00e7 kablosu parazitini kontrol edin. Terminal kartlar\u0131ndaki nem veya i\u00e7 yo\u011fu\u015fma beklenmedik durumlara neden olabilir <a href=\"https:\/\/www.aox-actuator.com\/tr\/blog\/actuator-valve-not-working-signs\/\" target=\"_blank\" rel=\"noreferrer noopener\">sinyal sapmas\u0131<\/a> nemli alanlarda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>4-20mA Akt\u00fcat\u00f6rler \u0130\u00e7in PLC Entegrasyon K\u0131lavuzu<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir elektrikli akt\u00fcat\u00f6r 4-20mA cihaz\u0131n\u0131 bir PLC sistemine entegre etmek, g\u00fc\u00e7 kayna\u011f\u0131n\u0131 d\u00f6ng\u00fc empedans\u0131yla e\u015fle\u015ftirmeyi gerektirir. G\u00fcvenilir bir elektrikli akt\u00fcat\u00f6r tasarlamak <a href=\"https:\/\/www.aox-actuator.com\/tr\/blog\/control-valve-modulation-onoff\/\" target=\"_blank\" rel=\"noreferrer noopener\">kontrol d\u00f6ng\u00fcs\u00fc<\/a> s\u00fcr\u00fcc\u00fc kapasitesini sa\u011flamak i\u00e7in toplam direnci hesaplamay\u0131 gerektirir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gerekli minimum d\u00f6ng\u00fc besleme voltaj\u0131n\u0131 hesaplamak i\u00e7in, maksimum 20mA ak\u0131m\u0131 toplam d\u00f6ng\u00fc direnciyle \u00e7arp\u0131n ve akt\u00fcat\u00f6r\u00fcn gerekli \u00e7al\u0131\u015fma bo\u015flu\u011funu ekleyin. Bu toplam, vericinin s\u00fcr\u00fc\u015f voltaj\u0131 s\u0131n\u0131rlar\u0131n\u0131 a\u015farsa, \u00fcst aral\u0131kta sinyal k\u0131rpma meydana gelir ve tam valf seyahatini engeller.<\/p>\n\n\n\n<style>\n  .hero-recommendation-vertical {\n    max-width: 420px;\n    margin: 32px auto;\n    background: #fff;\n    border-radius: 16px;\n    box-shadow: 0 4px 18px 0 rgba(60, 66, 87, 0.10);\n    overflow: hidden;\n    transition: box-shadow 0.2s;\n  }\n  .hero-link-vertical {\n    display: flex;\n    flex-direction: column;\n    align-items: center;\n    text-decoration: none;\n    color: inherit;\n    width: 100%;\n    transition: background 0.2s;\n  }\n  .hero-link-vertical:hover {\n    background: #f8f9fa;\n  }\n  .hero-image-vertical img {\n    display: block;\n    width: 100%;\n    height: 210px;\n    object-fit: cover;\n    background: #f4f4f4;\n  }\n  .hero-content-vertical {\n    padding: 28px 22px 24px 22px;\n    text-align: center;\n    width: 100%;\n  }\n  .hero-content-vertical h2 {\n    margin: 0 0 12px 0;\n    font-size: 1.3rem;\n    font-weight: 700;\n    color: #263238;\n    letter-spacing: 0.01rem;\n  }\n  .hero-content-vertical p {\n    margin: 0 0 18px 0;\n    font-size: 1rem;\n    color: #546e7a;\n    line-height: 1.5;\n  }\n  .hero-btn-vertical {\n    padding: 10px 26px;\n    background: #ffc107; \/* Changed button background color *\/\n    border: none;\n    border-radius: 6px;\n    font-size: 1rem;\n    font-weight: 600;\n    color: #fff;\n    cursor: pointer;\n    transition: background 0.2s, color 0.2s;\n    box-shadow: 0 2px 8px rgba(255,193,7,0.10); \/* Adjusted shadow color *\/\n  }\n  .hero-btn-vertical:hover {\n    background: #e0a800; \/* Darkened color for hover effect (approx 10-15%) *\/\n  }\n  @media (max-width: 600px) {\n    .hero-recommendation-vertical {\n      max-width: 98vw;\n    }\n    .hero-image-vertical img {\n      height: 160px;\n    }\n    .hero-content-vertical {\n      padding: 18px 8px 16px 8px;\n    }\n  }\n<\/style>\n<div class=\"hero-recommendation-vertical\">\n  <a href=\"https:\/\/www.aox-actuator.com\/tr\/product\/aox-vr-series-electric-actuator\/\" class=\"hero-link-vertical\" target=\"_blank\" rel=\"noopener\">\n    <div class=\"hero-image-vertical\">\n      <img decoding=\"async\" src=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2024\/09\/AOX-VR-series-electric-actuator.webp\" alt=\"AOX-VR Serisi Elektrikli Vana Akt\u00fcat\u00f6r\u00fc\">\n    <\/div>\n    <div class=\"hero-content-vertical\">\n      <p><strong>AOX-VR Serisi Elektrikli Vana Akt\u00fcat\u00f6r\u00fc<\/strong><\/p>\n      <p>\n      \u201cAOX-VR\u201d serisi, m\u00fckemmel hava ko\u015fullar\u0131na dayan\u0131kl\u0131l\u0131k ve darbe dayan\u0131kl\u0131l\u0131\u011f\u0131na sahip kompakt bir yap\u0131ya sahiptir.\n      <\/p>\n      <button class=\"hero-btn-vertical\">\u00dcr\u00fcn ve \u00c7\u00f6z\u00fcmleri Ke\u015ffedin<\/button>\n    <\/div>\n  <\/a>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcm<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Elektrikli akt\u00fcat\u00f6r 4-20mA d\u00f6ng\u00fcn\u00fcz\u00fc do\u011fru bir \u015fekilde kurmak, operasyonel kesinti s\u00fcresini \u00f6nler ve hassas ak\u0131\u015f kontrol\u00fcn\u00fc s\u00fcrd\u00fcr\u00fcr. Uzun vadeli performans\u0131 sa\u011flamak i\u00e7in devreyi \u00e7al\u0131\u015ft\u0131rmadan \u00f6nce d\u00f6ng\u00fc empedans\u0131n\u0131 ve bo\u015flu\u011funu do\u011frulay\u0131n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Y\u00fckseltme yaparken, y\u00fcksek performansl\u0131 <a href=\"https:\/\/www.aox-actuator.com\/tr\/product-category\/electric-actuator\/\" target=\"_blank\" rel=\"noreferrer noopener\">elektrikli vana akt\u00fcat\u00f6rleri<\/a>. sunan bir \u00fcreticiyle ortakl\u0131k kurmay\u0131 d\u00fc\u015f\u00fcn\u00fcn. Bu proaktif yakla\u015f\u0131m, sorun giderme s\u00fcresini azalt\u0131r ve mevcut donan\u0131m\u0131n\u0131zla sorunsuz entegrasyonu garanti eder.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>SSS<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1.<\/strong> <strong>4-20mA d\u00f6ng\u00fcs\u00fcn\u00fc paralel olarak kablolarsam ne olur?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ak\u0131m d\u00f6ng\u00fclerini paralel olarak kablolamak, sinyal ak\u0131m\u0131n\u0131 cihazlar aras\u0131nda b\u00f6ler, bu da do\u011fru kalibrasyonu engeller ve yanl\u0131\u015f okumalara veya d\u00f6ng\u00fc hatalar\u0131na neden olabilir. Geleneksel bir 4-20mA ak\u0131m d\u00f6ng\u00fcs\u00fc, ayn\u0131 ak\u0131m\u0131n her d\u00f6ng\u00fc cihaz\u0131ndan ge\u00e7mesi i\u00e7in seri olarak kablolan\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2.<\/strong> <strong>Kalkan telinin her iki ucu topraklanmal\u0131 m\u0131?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Genellikle, toprak d\u00f6ng\u00fcs\u00fc paraziti riskini azaltmak i\u00e7in kalkan\u0131 tek bir u\u00e7tan, genellikle PLC kabini taraf\u0131na topraklay\u0131n. Her iki ucun topraklanmas\u0131, kontrol sinyaline g\u00fcr\u00fclt\u00fc getirebilecek bir elektrik yolu olu\u015fturur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Analog d\u00f6ng\u00fcn\u00fcn \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 nas\u0131l do\u011frular\u0131m?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ak\u0131m\u0131 aktif devre \u00fczerinden \u00f6l\u00e7mek i\u00e7in dijital bir multimetreyi seri olarak kullan\u0131n. 4mA'n\u0131n valfi 0%'ye konumland\u0131rd\u0131\u011f\u0131n\u0131, 12mA'n\u0131n 50%'ye konumland\u0131rd\u0131\u011f\u0131n\u0131 ve 20mA'n\u0131n 0% a\u00e7\u0131k konuma getirdi\u011fini do\u011frulay\u0131n.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div style=\"--wp--block-button--width: 50;\" class=\"wp-block-button has-custom-width wp-block-button__width wp-block-button__width-50\"><a class=\"wp-block-button__link has-white-color has-text-color has-background has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/www.aox-actuator.com\/tr\/contact\/\" style=\"background-color:#ffc107;font-style:normal;font-weight:700\" target=\"_blank\" rel=\"noreferrer noopener\">Bize Ula\u015f\u0131n<\/a><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Quick Answer To wire an electric actuator 4-20mA signal, connect the controller&#8217;s positive terminal to the actuator&#8217;s positive analog input according to the manufacturer&#8217;s wiring diagram.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":5430,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[72],"tags":[],"class_list":["post-5429","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Electric Actuator 4-20mA Wiring Guide | AOX<\/title>\n<meta name=\"description\" content=\"Learn how to wire an electric actuator for 4-20mA signal control. This guide covers wiring diagrams, PLC integration, signal comparison, and common troubleshooting tips.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aox-actuator.com\/tr\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electric Actuator 4-20mA Wiring Guide | AOX\" \/>\n<meta property=\"og:description\" content=\"Learn how to wire an electric actuator for 4-20mA signal control. This guide covers wiring diagrams, PLC integration, signal comparison, and common troubleshooting tips.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aox-actuator.com\/tr\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/\" \/>\n<meta property=\"og:site_name\" content=\"High-Performance Actuator Manufacturer | Customized Valve Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AoxiangAutoControl\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-15T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-31T09:33:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1667\" \/>\n\t<meta property=\"og:image:height\" content=\"944\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"aoxiangadmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"aoxiangadmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/\"},\"author\":{\"name\":\"aoxiangadmin\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#\\\/schema\\\/person\\\/ade79677436334c988019b081ff74b13\"},\"headline\":\"How to Wire an Electric Actuator for 4-20mA Signal Control?\",\"datePublished\":\"2026-08-15T00:00:00+00:00\",\"dateModified\":\"2026-08-31T09:33:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/\"},\"wordCount\":841,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image5-1.webp\",\"articleSection\":[\"Technical Guides\"],\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/\",\"url\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/\",\"name\":\"Electric Actuator 4-20mA Wiring Guide | AOX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image5-1.webp\",\"datePublished\":\"2026-08-15T00:00:00+00:00\",\"dateModified\":\"2026-08-31T09:33:15+00:00\",\"description\":\"Learn how to wire an electric actuator for 4-20mA signal control. This guide covers wiring diagrams, PLC integration, signal comparison, and common troubleshooting tips.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image5-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image5-1.webp\",\"width\":1667,\"height\":944,\"caption\":\"AOX electric valve actuator for precise 4\u201120mA signal control\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/blog\\\/technical-guides\\\/wire-electric-actuator-4-20ma-signal-control\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aox-actuator.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Wire an Electric Actuator for 4-20mA Signal Control?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#website\",\"url\":\"https:\\\/\\\/www.aox-actuator.com\\\/\",\"name\":\"AOX Auto-Control Technology Co., Ltd\",\"description\":\"We offer high-quality actuators and valve automation solutions tailored for various industries. We are dedicated to providing the best service for you.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aox-actuator.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#organization\",\"name\":\"Professional electric valve actuator manufacturer\",\"url\":\"https:\\\/\\\/www.aox-actuator.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/icon.jpg\",\"contentUrl\":\"https:\\\/\\\/www.aox-actuator.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/icon.jpg\",\"width\":80,\"height\":80,\"caption\":\"Professional electric valve actuator manufacturer\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/AoxiangAutoControl\",\"https:\\\/\\\/www.youtube.com\\\/@zhejiangaoxiangauto-contro2634\",\"https:\\\/\\\/www.linkedin.cn\\\/incareer\\\/company\\\/zhejiang-aoxiang-auto-control-technology-co--ltd?trk=public_profile_topcard-current-company\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.aox-actuator.com\\\/#\\\/schema\\\/person\\\/ade79677436334c988019b081ff74b13\",\"name\":\"aoxiangadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g\",\"caption\":\"aoxiangadmin\"},\"sameAs\":[\"http:\\\/\\\/aox-actuator.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Elektrik Akt\u00fcat\u00f6r 4-20mA Kablolama K\u0131lavuzu | AOX","description":"4-20mA sinyal kontrol\u00fc i\u00e7in elektrikli akt\u00fcat\u00f6r\u00fcn nas\u0131l ba\u011flanaca\u011f\u0131n\u0131 \u00f6\u011frenin. Bu k\u0131lavuz, kablolama \u015femalar\u0131n\u0131, PLC entegrasyonunu, sinyal kar\u015f\u0131la\u015ft\u0131rmas\u0131n\u0131 ve yayg\u0131n sorun giderme ipu\u00e7lar\u0131n\u0131 kapsar.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aox-actuator.com\/tr\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/","og_locale":"tr_TR","og_type":"article","og_title":"Electric Actuator 4-20mA Wiring Guide | AOX","og_description":"Learn how to wire an electric actuator for 4-20mA signal control. This guide covers wiring diagrams, PLC integration, signal comparison, and common troubleshooting tips.","og_url":"https:\/\/www.aox-actuator.com\/tr\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/","og_site_name":"High-Performance Actuator Manufacturer | Customized Valve Automation","article_publisher":"https:\/\/www.facebook.com\/AoxiangAutoControl","article_published_time":"2026-08-15T00:00:00+00:00","article_modified_time":"2026-08-31T09:33:15+00:00","og_image":[{"width":1667,"height":944,"url":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp","type":"image\/webp"}],"author":"aoxiangadmin","twitter_card":"summary_large_image","twitter_misc":{"Yazan:":"aoxiangadmin","Tahmini okuma s\u00fcresi":"5 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#article","isPartOf":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/"},"author":{"name":"aoxiangadmin","@id":"https:\/\/www.aox-actuator.com\/#\/schema\/person\/ade79677436334c988019b081ff74b13"},"headline":"How to Wire an Electric Actuator for 4-20mA Signal Control?","datePublished":"2026-08-15T00:00:00+00:00","dateModified":"2026-08-31T09:33:15+00:00","mainEntityOfPage":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/"},"wordCount":841,"commentCount":0,"publisher":{"@id":"https:\/\/www.aox-actuator.com\/#organization"},"image":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp","articleSection":["Technical Guides"],"inLanguage":"tr","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/","url":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/","name":"Elektrik Akt\u00fcat\u00f6r 4-20mA Kablolama K\u0131lavuzu | AOX","isPartOf":{"@id":"https:\/\/www.aox-actuator.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#primaryimage"},"image":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp","datePublished":"2026-08-15T00:00:00+00:00","dateModified":"2026-08-31T09:33:15+00:00","description":"4-20mA sinyal kontrol\u00fc i\u00e7in elektrikli akt\u00fcat\u00f6r\u00fcn nas\u0131l ba\u011flanaca\u011f\u0131n\u0131 \u00f6\u011frenin. Bu k\u0131lavuz, kablolama \u015femalar\u0131n\u0131, PLC entegrasyonunu, sinyal kar\u015f\u0131la\u015ft\u0131rmas\u0131n\u0131 ve yayg\u0131n sorun giderme ipu\u00e7lar\u0131n\u0131 kapsar.","breadcrumb":{"@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#primaryimage","url":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp","contentUrl":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2026\/08\/image5-1.webp","width":1667,"height":944,"caption":"AOX electric valve actuator for precise 4\u201120mA signal control"},{"@type":"BreadcrumbList","@id":"https:\/\/www.aox-actuator.com\/blog\/technical-guides\/wire-electric-actuator-4-20ma-signal-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aox-actuator.com\/"},{"@type":"ListItem","position":2,"name":"How to Wire an Electric Actuator for 4-20mA Signal Control?"}]},{"@type":"WebSite","@id":"https:\/\/www.aox-actuator.com\/#website","url":"https:\/\/www.aox-actuator.com\/","name":"AOX Oto-Kontrol Teknolojisi A.\u015e.","description":"\u00c7e\u015fitli end\u00fcstrilere \u00f6zel y\u00fcksek kaliteli akt\u00fcat\u00f6rler ve vana otomasyon \u00e7\u00f6z\u00fcmleri sunuyoruz. Sizin i\u00e7in en iyi hizmeti sunmaya adad\u0131k kendimizi.","publisher":{"@id":"https:\/\/www.aox-actuator.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aox-actuator.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/www.aox-actuator.com\/#organization","name":"Profesyonel elektrikli vana akt\u00fcat\u00f6r \u00fcreticisi","url":"https:\/\/www.aox-actuator.com\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.aox-actuator.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2024\/09\/icon.jpg","contentUrl":"https:\/\/www.aox-actuator.com\/wp-content\/uploads\/2024\/09\/icon.jpg","width":80,"height":80,"caption":"Professional electric valve actuator manufacturer"},"image":{"@id":"https:\/\/www.aox-actuator.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AoxiangAutoControl","https:\/\/www.youtube.com\/@zhejiangaoxiangauto-contro2634","https:\/\/www.linkedin.cn\/incareer\/company\/zhejiang-aoxiang-auto-control-technology-co--ltd?trk=public_profile_topcard-current-company"]},{"@type":"Person","@id":"https:\/\/www.aox-actuator.com\/#\/schema\/person\/ade79677436334c988019b081ff74b13","name":"aoxiangadmin","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/secure.gravatar.com\/avatar\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93aff415514bd814648ce79dba79eda7b10083835a9415e821ea29da31948aad?s=96&d=mm&r=g","caption":"aoxiangadmin"},"sameAs":["http:\/\/aox-actuator.com"]}]}},"_links":{"self":[{"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/posts\/5429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/comments?post=5429"}],"version-history":[{"count":3,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/posts\/5429\/revisions"}],"predecessor-version":[{"id":5508,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/posts\/5429\/revisions\/5508"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/media\/5430"}],"wp:attachment":[{"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/media?parent=5429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/categories?post=5429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aox-actuator.com\/tr\/wp-json\/wp\/v2\/tags?post=5429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}